7. Winterizing the Streamline Pool
A StreamLine Pool may be used year round, even in colder cli-
mates. If you will not be using the pool during the winter in an
area where freezing is a problem, special consideration must be
taken to protect the pool and ancillary equipment if either is locat-
ed outside. If you have any questions regarding precautions to take
against freezing, please call our Customer Service Department at
(800) 910-2714.
8. Water Quality Error Codes
Hr
An internal hardware error has been detected in
in.xe. Contact Customer Service.
HL
The system has shut the heater down because the
temperature at the heater has reached 119°F (48°C).
Do not enter the water! Remove the spa cover and
allow the water to cool down, then shut power off
and power your spa up again to reset the system.
AOH
Temperature inside the spa skirt is too high, caus-
ing the internal temperature in the in.xe to increase
above normal limits. Open skirt and wait until error
clears.
FLO
The system does not detect any water ow while
the primary pump is running. Check and open wa-
ter valves. Check for water level. Clean lter. If the
problem persists, call Customer Service.
Prr
A problem is detected with the temperature probe.
Call Customer Service.
OH
The water temperature in the spa has reached 108°F
(42°C). Do not enter the water! Remove the spa
cover and allow the water to cool down to a low-
er temperature. Call Customer Service if problem
persists.
UPL
No low level conguration software has been in-
stalled into the system. Call Customer Service.
13