9. Propulsion System and Water Quality System Troubleshooting
Symptom Possible Cause Solution
Propulsion System
1.) 25 amp fuse blown inside the 1.) Check for continuity on the fuse and Pump
Wont Turn On
heater controller replace if necessary
2.) No power to pump receptacle 2.) 25 amp fuse may be blown inside heater
on the heater controller controller. If fuse is not blown, turn off
breaker for 5 minutes and reset. If still no
voltage to pump receptacle, replace heater
controller.
3.) Propulsion system pump is not plugged in 3.) Plug pump in. Plug must “lock” into place
4.) Damaged Key 1 button on keypad display 4.) If pump 1 icon does not appear when
pressing Key 1, replace the keypad
No Swim Current when
1.) Water level is to low 1.) Add water to pool. The water level
propulsion system pump is on
should cover the honeycomb grill on
the front of the propulsion system
housing.
2.) Slide valve is in the closed position 2.) Open slide valve
3.) Air trapped in plumbing 3.) With the propulsion system running on high
speed, slowly unthread the air plug at the top
of the pump housing to allow air to escape.