Level and interface measurement in liquids
Application
• Rod, rope or coax probe
• Process connection: Starting 3/4" thread or flange
• Process temperature: –50 to +200 °C (–58 to +392 °F)
• Process pressure: –1 to +40 bar (–14.5 to +580 psi)
• Maximum measuring range: Rod 10 m (33 ft); rope 45 m (148 ft); coax 6 m (20 ft)
• Accuracy: ±2 mm (±0.08 in)
• International explosion protection certificates; EN10204-3.1
• Linearity protocol (3-point)
Your benefits
• Reliable measurement even for changing product and process conditions
• HistoROM data management for easy commissioning, maintenance and
diagnostics
• Highest reliability due to Multi-Echo Tracking
• Seamless integration into control or asset management systems
• Intuitive user interface in national languages
Products Solutions Services
Technical Information
Levelflex FMP51
Modbus
Guided wave radar
TI01454F/00/EN/01.19
71429962
2019-02-28