Bendingtorque[M]onrodprobes,diameter8mm(1/3”)
Probelength[ ]inmetersL
N
v=0.5m/s
v=0.7m/s
v=1.0m/s
max.bending torque
0.4 0.8 1.2 1.6 2 2.4 2.8 3.2 3.6 4
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
Bending [Nm]
torque
A0014182-EN
Bending strength of coax probes
Sensor Feature 060 Process connection Probe Bending strength
[Nm]
FMP51 UA, UB Thread G¾ oder NPT¾ Coax 316L, Ø 21,3
mm
60
Thread G1½ or
NPT1½
Flange
Coax 316L, Ø 42,4
mm
300
UC, UD Flange Coax AlloyC, Ø
42,4 mm
300