Levelflex FMP51 Modbus
Endress+Hauser 41
Installation at an angle
a
LN
A0014145
For mechanical reasons, the probe should be installed as vertically as possible.
With inclined installations the probe length has to be adjusted in dependence to the installation
angle.
Up to LN = 1 m (3.3 ft): α = 30°
Up to LN = 2 m (6.6 ft): α = 10°
Up to LN = 4 m (13.1 ft): α = 5°