Operating Instructions
Micropilot FMR20
HART
Free space radar
For bulk solids
BA02096F/00/EN/02.21
71534964
2021-08-02
01.00.zz (Device firmware)

Table of Contents

Other manuals for Endress+Hauser Micropilot FMR20 HART

Questions and Answers

  • S
    Sean DavisSep 3, 2025
    What to do if my Endress+Hauser Radar device does not respond?
    • J
      Jessica ReedSep 4, 2025
      If your Endress+Hauser Radar device isn't responding, ensure the supply voltage matches the nameplate specifications by applying the correct voltage. Also, verify and correct the polarity of the supply voltage if it's wrong, and ensure proper electrical contact between the cables and terminals.
  • R
    Rachel BellSep 18, 2025
    What to do if Login via SmartBlue is not possible on Endress+Hauser Micropilot FMR20 HART Measuring Instruments?
    • M
      Morgan RubioSep 18, 2025
      If you can't log in via SmartBlue on your Endress+Hauser Measuring Instruments device and the device is being put into operation for the first time, enter the initial password (device serial number) and change it. Pay attention to lower/upper case when entering the serial number.
  • T
    Teresa GravesSep 16, 2025
    Why linearized output value not plausible on Endress+Hauser Radar?
    • J
      josephalecSep 16, 2025
      If the linearized output value is not plausible on your Endress+Hauser Radar, check the linearization table using SmartBlue or FieldCare/DeviceCare. Also, check the vessel selection in the linearization module.
  • J
    Jonathan FranklinSep 14, 2025
    What to do if RIA15 start sequence keeps running through on Endress+Hauser Radar?
    • E
      Eddie JohnsonSep 14, 2025
      If the RIA15 start sequence keeps running through on your Endress+Hauser Radar, try to increase the supply voltage and switch off the backlight.
  • M
    Micheal ClarkSep 12, 2025
    What to do if display values are not plausible on Endress+Hauser Radar?
    • D
      Desiree HansonSep 12, 2025
      If the display values of your Endress+Hauser Radar are not plausible, log off FieldCare/DeviceCare and disconnect, or log off SmartBlue and disconnect, as connection via SmartBlue has priority.
  • C
    Colleen ZimmermanSep 12, 2025
    How to fix Endress+Hauser Radar device not visible in the live list?
    • A
      anthony77Sep 12, 2025
      If the Endress+Hauser Radar device is not visible in the live list, enable the Bluetooth function on your smartphone or tablet. If the issue persists, the Bluetooth function of the sensor might be disabled, perform recovery sequence.
  • G
    gbrownSep 9, 2025
    Why is my Endress+Hauser Radar device measuring incorrectly?
    • S
      Spencer GarciaSep 9, 2025
      If your Endress+Hauser Radar device is measuring incorrectly, check and correct the parameter configuration. Also, carry out mapping.
  • J
    Jamie LloydSep 7, 2025
    What to do if my Endress+Hauser Radar RIA15 has no display?
    • L
      lanecraigSep 7, 2025
      If the RIA15 has no display, correct the polarity of the supply voltage if it is wrong and ensure proper electrical contact between the cables and the terminals. If the issue persists, the RIA15 may be defective and needs replacement.
  • J
    Jacob SanchezSep 5, 2025
    Why is HART communication not functioning on my Endress+Hauser Radar?
    • K
      kristencainSep 5, 2025
      If you're experiencing issues with HART communication on your Endress+Hauser Radar device, make sure the communication resistor (250 ?) is correctly installed. Also, verify that the Commubox is connected properly. Check the communication resistor and connections of the Commubox.
  • H
    Haley HarrisAug 20, 2025
    What to do if my Endress+Hauser Measuring Instrument device does not respond?
    • D
      David TaylorAug 21, 2025
      If your Endress+Hauser Measuring Instrument device isn't responding, there are several potential causes: * The supply voltage might not match the specifications on the nameplate. Ensure you apply the correct voltage. * The polarity of the supply voltage could be incorrect. Correct the polarity. * The cables may not be making proper contact with the terminals. Ensure good electrical contact between the cable and the terminal.

Endress+Hauser Micropilot FMR20 HART Specifications

General IconGeneral
BrandEndress+Hauser
ModelMicropilot FMR20 HART
CategoryMeasuring Instruments
LanguageEnglish