Operating Instructions
Micropilot FMR10
Free space radar
BA01577F/00/EN/02.16
71331355
2020-03-30
01.00.zz (Device firmware)

Table of Contents

Other manuals for Endress+Hauser Micropilot FMR10

Questions and Answers

  • M
    Michael HoffmanJul 26, 2025
    What to do if my Endress+Hauser Radar device is not responding?
    • N
      Nicholas FordJul 26, 2025
      If the Endress+Hauser Radar device is not responding, it could be due to several reasons. First, ensure that the supply voltage matches the value indicated on the device's nameplate and apply the correct voltage if it doesn't. Also, check that the polarity of the supply voltage is correct. Finally, verify that all connecting cables are securely in contact with the terminals and correct any loose connections.
  • J
    Jeffrey CostaJul 31, 2025
    What to do if the Endress+Hauser Radar device cannot be operated via SmartBlue?
    • M
      Marcus HerreraJul 31, 2025
      If you cannot operate the Endress+Hauser Radar device via SmartBlue, ensure you are entering the correct password. If the password has been forgotten, contact Endress+Hauser Service for assistance.
  • T
    Taylor DawsonAug 6, 2025
    How to fix 'Device not accessible via SmartBlue' for Endress+Hauser Radar?
    • C
      connieandersonAug 6, 2025
      If the Endress+Hauser Radar device is not accessible via SmartBlue, there might be several reasons: * Ensure that the Bluetooth function is enabled on your smartphone or tablet. * If the Bluetooth function of the sensor is disabled, perform a recovery sequence.
  • J
    Jesse HillAug 12, 2025
    Why does my Endress+Hauser Radar device measure incorrectly?
    • J
      Jill WilliamsAug 12, 2025
      If the Endress+Hauser Radar device measures incorrectly, it might be due to a configuration error. To resolve this, check and correct the parameter configuration and perform mapping.
  • E
    Edward LaneAug 18, 2025
    What causes a linearized output value to be not plausible in Endress+Hauser Radar?
    • S
      Sarah BlackwellAug 18, 2025
      If the linearized output value of the Endress+Hauser Radar is not plausible, there may be a linearization error. Check the linearization table using SmartBlue.

Summary

2 Basic safety instructions

2.1 Requirements for personnel

Specifies qualifications, authorization, and familiarity required for personnel.

2.2 Designated use

Describes the intended use and limitations of the measuring device, including media compatibility.

2.4 Operational safety

Details safe operation, unauthorized modifications, and repair precautions.

3 Product description

5 Installation

5.1.3 Position for installation on a vessel

Recommends optimal placement within a vessel to avoid interference.

6 Electrical connection

7 Operability

8 Commissioning and operation

8.2 Commissioning via SmartBlue (App)

Details the process for commissioning the device using the SmartBlue mobile application.

9 Diagnostics and troubleshooting

9.1 General errors

Lists common device errors, their possible causes, and recommended solutions.

9.2 Error - SmartBlue operation

Troubleshoots common issues encountered when using the SmartBlue app.

9.4 List of diagnostic events

Provides a comprehensive table of diagnostic events, their codes, and remedy instructions.

10 Maintenance

13 Operating menu

13.3 Diagnostics submenu

Details diagnostic functions, error messages, and signal quality indicators.

Endress+Hauser Micropilot FMR10 Specifications

General IconGeneral
Device TypeRadar level transmitter
Measuring PrincipleFMCW Radar
Power Supply10.5 to 36 V DC
Ingress ProtectionIP66 / IP67
Output Signal4 to 20 mA, HART
CommunicationHART
ApprovalATEX, IECEx, FM
Process Temperature-40 to +80 °C