Micropilot FMR10 Operating menu
Endress+Hauser 67
13.3.2 "Simulation" submenu
Navigation Diagnostics → Simulation
Simulation
Navigation Diagnostics → Simulation → Simulation
Description Select process variable to be simulated. The Simulation is used to simulate specific
measuring values or other conditions. This helps to check the correct configuration of the
device and connected control units.
Selection • Off
• Current output
• Distance
Factory setting Off
Value current output
Navigation Diagnostics → Simulation → Value current output 1
Description Defines the value of the simulated output current.
User entry 3.59 to 22.5 mA
Factory setting 3.59 mA
Process variable value
Navigation Diagnostics → Simulation → Process variable value
Description Value of the simulated process variable. Downstream measured value processing and the
signal output use this simulation value. In this way, users can verify whether the
measuring device has been configured correctly.
User entry 0 to 20 m
Factory setting 0 m