EasyManua.ls Logo

Endress+Hauser Levelflex M FMP41C User Manual

Endress+Hauser Levelflex M FMP41C
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
BA00244F/00/EN/13.10
71120272
Valid as of software version:
01.04.zz
Operating Instructions
Levelflex M FMP40
Guided Level-Radar

Table of Contents

Other manuals for Endress+Hauser Levelflex M FMP41C

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Levelflex M FMP41C and is the answer not in the manual?

Endress+Hauser Levelflex M FMP41C Specifications

General IconGeneral
Device TypeLevel transmitter
CommunicationHART, PROFIBUS PA, FOUNDATION Fieldbus
Process Pressure-1 to +40 bar
Output Signal4-20 mA HART, PROFIBUS PA, Foundation Fieldbus
Housing MaterialStainless steel
Probe TypeRod probe, Cable probe
ApprovalsATEX, IECEx, FM, CSA
Protection ClassIP66/IP68
MaterialStainless Steel, PTFE
ApplicationLevel measurement in liquids and solids
Process Temperature-40 to +200 °C
Power Supply10.5 to 42 V DC