Do you have a question about the Endress+Hauser Levelflex M FMP45 and is the answer not in the manual?
Housing Material | Aluminum, stainless steel |
---|---|
Communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
Device Type | Guided radar / TDR |
Measuring Principle | Guided radar |
Application | Continuous level measurement of liquids and solids |
Process Temperature | -40 to +200 °C |
Process Pressure | -1 to 40 bar (-14.5 to 580 psi) |
Output Signal | 4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus |
Probe Type | Rod or cable |
Approvals | ATEX, FM, CSA, IEC Ex |
Material | Stainless steel, PTFE |
Protection Rating | IP66/67 |
Accuracy | ± 5 mm |