Levelflex M FMP40 and FMP45 7 Description of Instrument Functions
Endress+Hauser 39
7 Description of Instrument Functions
7.1 Function group "basic setup"
7.1.1 Function "measured value"
This function displays the current measured value in the selected unit. The number of places after
decimal point can be selected in the "no.of decimals" function.
7.1.2 Function "Dielectric const."
By this function the dielectric product property of the upper product phase is defined. The value of
the dielectric constant can be identified also by activating the table of dielectric values by clicking
on the tank drawing.
!
Note!
The value of the dielectric constant can be identified also by activating the table of dielectric values
by clicking on the tank drawing. The listed dielectric values may vary from the real dielectric values
of the product.
7.1.3 Function "Dist. total level"
The total level is entered by this function. It is needed to compensate gaseous phase which might
be present.
!
Note!
After entereing the "Dist. total level" function, the "upper blocking dist." function is automati-
cally set to the same value!