Levelflex M FMP41C with HART/4...20 mA Installation
Endress + Hauser 15
3.3 Installation
3.3.1 Mounting kit
In addition to the tool needed for flange mounting, you will require the following tool:
4 mm Allen wrench for turning the housing.
3.3.2 Mounting probes
"
Caution!
If there is a risk of electrostatic discharge from the product, then both processconnection and rope
must be earthed before the probe is lowered into the silo.
Insert probe
Uncoil rope and lower it slowly and carefully
into the silo.
Do not kink the rope
Avoid any backlash, since this mightdamage
the probe or the silo fittings.
!
Note!
Flanges: bolt the flange in positionbefore
inserting the cable into the silo.
Be sure to use unpainted metal bolts
toensure good electrical contact
betweenprobe flange and process flange.
L00-FMP4xxxx-17-00-00-en-056
Uncoil rope and lower
probe slowly and
carefully into the silo