Levelflex M FMP41C with HART/4...20 mA Installation
Endress + Hauser 15
3.3 Installation
3.3.1 Mounting kit
In addition to the tool needed for flange mounting, you will require the following tool:
• 4 mm Allen wrench for turning the housing.
3.3.2 Mounting probes
"
Caution!
If there is a risk of electrostatic discharge from the product, then both processconnection and rope
must be earthed before the probe is lowered into the silo.
Insert probe
• Uncoil rope and lower it slowly and carefully
into the silo.
• Do not kink the rope
• Avoid any backlash, since this mightdamage
the probe or the silo fittings.
•
!
Note!
– Flanges: bolt the flange in positionbefore
inserting the cable into the silo.
– Be sure to use unpainted metal bolts
toensure good electrical contact
betweenprobe flange and process flange.
L00-FMP4xxxx-17-00-00-en-056
Uncoil rope and lower
probe slowly and
carefully into the silo