Levelflex M FMP40 FOUNDATION Fieldbus Mounting
Endress+Hauser 11
3Mounting
3.1 Quick installation guide
L00-FMP4xxxx-17-00-00-en-029
1. When using an aramid fibre seal and a process pressure of 40 bar: 140 Nm
Maximum permissible torque: 450 Nm
2. When using an aramid fibre seal and a process pressure of 40 bar: 25 Nm
Maximum permissible torque: 45 Nm
3
1
2
1½"
¾"
2.
1.
F12/F23 or T12 housing
Mounting with threaded boss
To simplify access to the
display and the terminal compartment
Allen key
4 mm / 0.1"
AF 60
AF 50
Caution!
Use only the
threaded boss
F12/F23 or T12 housing
Turn housing