3.3.3 General instructions
Normally use rod or coax probes for liquids. Rope probes are used in liquids for measuring ranges >
4m and with restricted ceiling clearance which does not allow the installation of rigid probes.
Minimum distance B of the probe to the container wall:
The wall clearance can be chosen as desired as long as the probe does not touch the tank wall.
!
Note!
There should be no metallic parts or persons moving when installation is made in plastic tanks,
also on the outside of the tank at a distance of 300 mm to the probe.
There should no bridges to the wall created by soiling or highly viscous media.
Mounting location
Do not mount rod or rope probes in the filling
curtain (3).
Mount rod and rope probes away from the
wall (B) at such a distance that, in the event of
build-up on the wall, there is still a minimum
distance of 100 mm between the probe and
the build-up.
Mount rod and rope probes as far away as
possible from installed fittings. "Mapping "
must be carried out during commissioning in
the event of distances < 300 mm.
Minimum distance of probe end to the
container floor (C):
Rope probe: 150 mm
Rod probe: 50 mm
When installing outdoors, it is recommended
that you use a protective cover (1) see
Accessories on ä 61.
L00-FMP4xxxx-17-00-00-xx-007
B
C
12
Other installations
Select the mounting location such that the
distance to internals (5) (e.g. limit switch,
struts) > is 300 mm over the entire length of
the probe, also during operation.
Probe must within the measuring span not
touch any internals during operation.
Optimization options
Interference echo suppression: Measurement
can be optimised by electronically tuning out
interference echoes.
L00-FMP41Cxx-17-00-00-xx-001