Micropilot FMR50 HART Electrical connection
Endress+Hauser 37
Terminal assignment 4-wire: 4-20 mA HART (10.4 to 48 V
DC
)
3
1
+
L+
4
2
-
L-
1
3
2
A0036516
 15 Terminal assignment 4-wire: 4-20 mA HART (10.4 to 48 V
DC
)
1 Connection 4-20 mA HART (active): terminals 3 and 4
2 Connection supply voltage: terminals 1 and 2
3 Terminal for cable screen