EasyManua.ls Logo

Endress+Hauser Micropilot FMR52 - Page 43

Endress+Hauser Micropilot FMR52
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR51, FMR52
Endress+Hauser 43
H
max
øD
A0023611
Nozzle diameter D Maximum nozzle height
H
max
Recommended antenna
1)
40 mm (1.5 in) 100 mm (3.9 in) BA: Horn 40mm/1-1/2"
50 mm (2 in) 150 mm (5.9 in) BB: Horn 50mm/2"
80 mm (3 in) 250 mm (9.8 in) BC: Horn 80mm/3"
100 mm (4 in) 500 mm (19.7 in) BD: Horn 100mm/4"
150 mm (6 in) 800 mm (31.5 in) BD: Horn 100mm/4"
1) Feature 070 of the product structure
If the antenna doesn't extend below the nozzle, observe the following:
The nozzle end must be smooth and free of burrs. If possible its edge should be rounded.
An interference echo suppression must be performed.
Please contact Endress+Hauser for applications with higher nozzles than those indicated in
the table.
For mounting in heigh nozzles the device is available in a version with an antenna extension
of up to 1 000 mm (39.4 in)
5)
The antenna extension may cause interference echoes in the near range. In this case it may
occur that the maximum measurable level is reduced.
Threaded connection
For devices with a threaded connection it may be necessary - depending on the antenna size -
to unmount the horn before fastening the device and to mount it again afterwards.
Tighten with the hexagonal nut only.
Tool : 55 mm hexagonal wrench
Maximum permissible torque: 60 Nm (44 lbf ft)
Mesurement from the outside through plastic walls (FMR50/FMR51)
Dielectric constant of the medium: ε
r
> 10
If possible, use an antenna 100 mm (4 in).
The distance from the lower edge of the antenna to the tank ceiling should be about
100 mm (4 in).
If possible, avoid mounting locations where condensation or build-up might occur.
In case of outdoor mounting, the space between antenna and vessel has to be protected from the
elements.
Do not mount any potential reflectors (e.g. pipes) outside the tank in the signal beam.
5) Feature 610 "Accessory mounted" of the product structure.