EasyManua.ls Logo

Endress+Hauser Micropilot FMR52 - Setup Menu

Endress+Hauser Micropilot FMR52
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating menu Micropilot FMR51, FMR52 FOUNDATION Fieldbus
126 Endress+Hauser
17.3 "Setup" menu
: Marks the navigation path to the parameter via the display and operating
module.
: Marks the navigation path to the parameter via an operating tool (e.g.
FieldCare).
: Marks parameters which can be locked via the software locking →  48.
Navigation  Setup
Distance unit
Navigation  Setup → Distance unit
Description Select distance unit.
Selection SI units
mm
m
US units
ft
in
Factory setting m
Tank type
Navigation  Setup → Tank type
Prerequisite Medium type (→  138) = Liquid
Description Select tank type.
Selection Bypass / pipe
Stilling well
Workbench test
Open channel
Sphere
Storage vessel
Process vessel standard
Process vessel with agitator
Wave guide antenna
Factory setting Depending on the antenna
Additional information Depending on the antenna some of the options mentioned above may not be available or
there may be additional options.

Table of Contents

Other manuals for Endress+Hauser Micropilot FMR52

Related product manuals