Tankvision configuration
33
7.2.5 Data Concentrator NXA821 specific settings
1. Associate Tank Scanner
Assign the Tank Scanner NXA820 to the Data Concentrator NXA821:
a. Login to the Data Concentrator NXA821 as "Supervisor".
b. In the navigation tree, click the "System" header.
c. Click "Global Settings" (below the "System" header).
d. In the main screen, click the header "Tank Scanner Unit And Tank Assignment".
e. Select all Tank Scanner units you want to assign to the Data Concentrator from the
"Available Units" list and move them to the "Selected Units" list using the arrow buttons.
All units in the "Selected Units" list will be assigned to the Data Concentrator.
f. Click the "Submit" button to save the settings.
2. Additional Settings (like groups)
Depending on your requirements, you can perform numerous further settings. For details refer
to BA339F/00/EN.
!
Note!
For details refer to BA339F/00/EN, "Tankvision NXA820, NXA821, NXA822 - Description of
Instrument Functions"
7.2.6 Host Link NXA822 specific settings
The Host Link NXA822 provides an interface for a host system to access inventory data from the
NXA820 unit.
To configure the Host Link settings, proceed as follows:
1. Login to the Host Link NXA822 as "Supervisor".
2. In the navigation tree, click the "System" header.
3. Click "Global Settings" (below the "System" header).
4. In the main screen, click the "Field Scan" header.
It contains the following subheaders which are used to configure the Host Link settings and to
start the Host Link:
Host Link Configuration
Modbus TCP Configuration (if the Modbus TCP protocol has been selected).
Modbus Serial (if the Modbus Serial protocol has been selected).
Entis+ (if the Entis+ serial protocol has been selected)
Start/Stop Host Link
For details please refer to BA339F/00/EN, "Tankvision NXA820, NXA821, NXA822 -
Description of Instrument Functions"

Other manuals for Endress+Hauser Tankvision NXA820