Accel CS Boiler - Gas Heat - Eighth Edition January, 2015 3
lights the burner. DO NOT try to light the burner by hand.
floor because some gas is heavier than air and will settle on the floor. See below.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your building
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair
technician to inspect the boiler and to replace any part of the control system and any gas
2. Set the thermostat(s) and aquastat(s) to their lowest setting.
3. Turn the service switch located on the front panel “OFF”.
4. This burner is equipped with an ignition device which automatically lights the burner. Do not try
to light the burner by hand.
5. Turn the external manual gas valve handle clockwise to the CLOSED” position (valve
handle will be perpendicular to gas piping).
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you
smell gas, STOP! Follow the safety information above. If you don’t smell gas, go to the next
step.
7. Turn manual gas valve handle counterclockwise to the “OPEN” position (valve handle
will be parallel to gas piping).
8. Set thermostat(s) to desired setting.
9. Turn on all electric power to the burner and boiler.
10. If the burner/boiler will not operate, follow the instructions “TO TURN OFF GAS TO THE
BURNER” below and call your service technician or gas supplier.
2. Turn the service switch on the Accel CS front panel “OFF”.
3. Turn the external manual gas valve handle clockwise to the “CLOSED” position.
WARNING: If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
External manual
gas shutoff valve,
supplied by installer.
A typical ball valve is shown,
some models do not have a
handle, your installation may
vary.