AM-IMPAQ-OM
Rev AB October 2018
Time of the charge
cycle (minutes)
Rated battery capacity
(AH)
Amp-hours returned
during charge cycle
Rated battery voltage (V)
Start of charge date
and time
Battery temperature at
start of charge (F)
Battery disconnect date
and time
State of charge at start of
charge (%)
Battery voltage at start of
charge (Vpc)
Battery voltage at end of
charge (Vpc)
Termination code (for
service tech)
STATUS
This menu displays the status of the charger’s internal counters (number of normal and partial
charges, faults by type, etc.).
Status Screen
Total number of charges – corresponds to the total of normally
terminated charges and charges terminated with or by faults
Number of charges normally terminated
Number of charges abnormally terminated
Number of faults recorded by the charger (see Fault Codes)
Number of charger temperature faults