EasyManua.ls Logo

Enerwave ZWN-RSM2-PLUS - 6.4 Indicator Command Class; 6.5 Configuration Command Class

Enerwave ZWN-RSM2-PLUS
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Endpoint
Grouping
Identifier
Max
Nodes
Mapping
Send Commands
Root Device
1(Lifeline
Group)
0x05
Endpoint1
Endpoint2
1. Switch Binary Report.
Switch will send Switch Binary Report when
Switch status changed.
2. Device Reset Locally.
Press and hold Z-Wave button at least 10
seconds.
3.Indicator Report
2
0x05
Endpoint1
1. Basic Set.
Switch will send Basic Set when Switch status
changed.
3
0x05
Endpoint2
1. Basic Set.
Switch will send Basic Set when Switch status
changed.
Endpoint 1
1
0x00
1. Switch Binary Report.
Switch will send Switch Binary Report when
Switch status changed.
2
0x05
1. Basic Set.
Switch will send Basic Set when Switch status
changed.
Endpoint 2
1
0x00
1. Switch Binary Report.
Switch will send Switch Binary Report when
Switch status changed.
2
0x05
1. Basic Set.
Switch will send Basic Set when Switch status
changed.
6.4 Indicator Command Class
The Receptacle support the Indicator Command Class, version 3 and support the Indicator ID 0x50
(Identify) and Properties ID 0x03, 0x04 and 0x05
6.5 Configuration Command Class
#
Name
Size
Range
Description
Default
0x05
Power on
status
1
0~2
When the device is powered on, the
initial status.
0= Off
1= On
2= Last State
0

Other manuals for Enerwave ZWN-RSM2-PLUS

Related product manuals