8
0x13
Child lockout
enable
1
0~1
Child lockout feature can enabled and
disabled local control.
0= Disable
1= Enable
0
0x14
Delayed off
time
1
0~240
Delay off means when users press
button to turn off the load, there’s a
reaction time.
0
Name
Info
Parame
ter
Numbe
r
Default
Value(de
c)
Max
Value(d
ec)
Min
Value(
dec)
Size
ReadOnl
y
Format
Altering
capabilit
y
Power on status
Power on status
0x05
0
2
0
1
No read-
only
Unsign
ed
integer
false
Child lockout
enable
Child lockout
enable
0x13
0
1
0
1
No read-
only
Unsign
ed
integer
false
Delayed off time
Delayed off time
0x14
0
240
0
1
No read-
only
Unsign
ed
integer
false