1
U P S
1000VA 3000VA
USER‘S MANUAL
2011/11 v 1.0

Questions and Answers

  • W
    wilsonrichardAug 12, 2025
    What to do if my Enplus UPS is overloaded?
    • E
      Eric NguyenAug 12, 2025
      If your Enplus UPS is overloaded in Line Mode, it means your equipment requires more power than the UPS can supply. To resolve this, turn off the least essential equipment connected to the UPS. If this action solves the overload, the UPS will revert from bypass to normal operation.
  • S
    Scott ThomasAug 16, 2025
    What to do if Enplus UPS is on battery?
    • K
      Keith RomanAug 16, 2025
      If your Enplus UPS is operating on battery power, immediately save your data and perform a controlled shutdown of your systems.
  • M
    Mike Morris PhDAug 19, 2025
    What happens if the Enplus Evo 1000VA UPS battery is low?
    • M
      Melissa MontgomeryAug 20, 2025
      If your Enplus UPS is running on battery power and the battery voltage is very low, the unit will shut down soon. It will restart automatically once acceptable power returns.
  • N
    nathanielbrownAug 25, 2025
    How to fix over-temperature on Enplus Evo 1000VA?
    • Y
      yryanAug 25, 2025
      If your Enplus UPS is overheating due to high ambient temperature: * Ensure that the fans and vent holes are not blocked. * Verify that the surrounding temperature is not above 40°C. If the problem persists after checking these conditions, contact your service representative.
  • A
    Andrew NewmanAug 27, 2025
    Why does my Enplus UPS show a site wiring fault?
    • M
      Michael Meyer DDSAug 27, 2025
      A site wiring fault on your Enplus UPS indicates voltage is detected between neutral and ground. This could be due to the UPS mains connector polarity being wrong (rotate the connector if it's a Schuko). It can also mean the UPS is installed to a mains supply without ground. See page 15 on how to disable the Site wiring alarm.
  • J
    Jose BuchananAug 31, 2025
    What to do if Enplus Evo 1000VA is over-charged?
    • J
      Jo NelsonAug 31, 2025
      If your Enplus UPS is overcharging its batteries, turn off the protected loads and then turn off the UPS. After this, contact your local dealer for assistance.
  • N
    Nicole GutierrezSep 3, 2025
    What causes a bus fault in an Enplus UPS?
    • K
      kristimillerSep 3, 2025
      A bus fault in your Enplus UPS is caused by high internal DC bus voltage. To address this, turn off the protected loads, then turn off the UPS, and contact your local dealer.
  • M
    Melissa HarrisSep 7, 2025
    What to do if Enplus Evo 1000VA UPS charger failure?
    • E
      Elizabeth ClaySep 8, 2025
      If the charger on your Enplus UPS has failed, phone your local dealer.

Summary

Critical Safety Instructions and Precautions

General Safety Guidelines

Instructions for installation, maintenance, and operation by any user.

Installation Environment Warnings

Intended for controlled environments with a max ambient temperature of 40°C.

Electrical Shock Hazard Warnings

Alerts to electric shock risks from heat sinks, internal parts, and battery supply.

User Serviceability and Fuse Replacement

No user-serviceable parts; refer servicing to qualified personnel; use correct fuses.

Battery Connection and Handling Safety

Do not disconnect battery under load; disconnect poles for service; follow battery precautions.

Operational Cautions and Safety Symbols

Voltage Hazard Awareness

Unit carries dangerous voltage even when unplugged due to internal battery power.

Safe Installation Practices

Install indoors with controlled temperature/humidity to minimize shock risk.

Servicing and Power Disconnection

Only qualified personnel should service; ensure power is off and disconnected before maintenance.

Safety Information and User Responsibilities

Installation Environment Hazard Awareness

Avoid hazardous environments; electrical hazards can be fatal if not acknowledged.

UPS Cabinet Access and Servicing

Do not open cabinet; high voltage present. Only qualified technicians should service.

Connecting the UPS to Power and Loads

Computer and Alarm Communication Interfaces

Connecting UPS to a Computer

Using power management software and cables for UPS-PC communication via RS232 or USB.

User Guide: UPS Operation Basics

Starting and Shutting Down the UPS

Step-by-step guide for starting the UPS, performing inspections, and shutting it down safely.

Front Panel Button Functions Explained

Details the ON/OFF button for power control and the Enter button for checking UPS status.

Control Panel Interface and Indicators

Button Navigation and Function Selection

Explains using Enter and Function buttons to navigate and select UPS functions and settings.

Understanding Control Panel LEDs

Describes the meaning of ON, ON-LINE, ON-BAT, BYPASS, and FAULT LED indicators.

UPS Status Display and Measurement Meters

UPS Meters: Voltage and Frequency

Details LCD display of output/input voltage, frequency, and battery voltage.

UPS Configuration Settings and Options

Entering and Navigating Configuration Mode

Steps to enter configuration mode and scroll through parameters using buttons.

Interpreting UPS Alarms and Messages

UPS Audible Alarm Indicators

Explains audible alarms for battery status, bypass, and internal faults.

Troubleshooting Common UPS Faults

Overload, Battery, and Over-Charge Issues

Troubleshooting steps for output overload, battery test, over-charge, and low battery conditions.

Operational and Environmental Faults

Diagnosing issues like on-battery, charger failure, over-temperature, and output short circuits.

Line, Wiring, and Abnormal Faults

Troubleshooting for bus fault, site wiring fault, and line abnormal conditions.

UPS Maintenance and Battery Safety

Critical Battery Handling Precautions

Warnings about electrical shock, burns from short circuits, and required safety measures.

Battery Replacement and Disconnection Rules

Use identical batteries; do not disconnect while in Battery mode.

Manual Bypass Operation: Online to Bypass Mode

Configuring UPS for Manual Bypass

Steps to set up UPS for manual bypass via LCD display settings.

Switching UPS to Bypass Mode

Procedure to switch UPS from ONLINE to BYPASS using external switch and verifying status.

Manual Bypass Operation: Bypass to Online Mode

Configuring UPS for Online Mode

Steps to set up UPS to switch from bypass back to online mode.

Switching UPS to Online Mode

Procedure to switch UPS from BYPASS to ONLINE using external switch and verifying status.

Enplus Evo UPS 1000VA Specifications

General IconGeneral
BrandEnplus
ModelEvo UPS 1000VA
CategoryUPS
LanguageEnglish