Pin Out Descriptions Completing the Installation
DFE-Platinum Series Hardware Installation Guide 3-17
Completing the Installation
CompletingtheDFEmoduleinstallationdependsonifthemoduleisbeinginstalledin:
•anewDFEmodulesystem(refertoCompletingtheInstallationofaNewSystemon
page 317),or
•anestablished,operatingDFEmodulesystem(refertoCompletingtheInstallationofa
DFEPlatinumModuleinan
ExistingSystemonpage 319).
Completing the Installation of a New System
InanewsystemofDFEmodules,oneoftheinstalledDFEmoduleswillbecomethemanagement
moduleonchassispowerup,andallDFEmoduleswillautomaticallybesettothefactorydefault
values.AcompletelistofthefactorydefaultvaluesareprovidedinChapter3oftheEnterasys
MatrixDFEPlatinumSeriesConfigurationGuide.
AfterinstallingallDFEPlatinummodulesintothehostchassisandmakingtheconnectionstothe
network,proceedtothefollowingFirstTimeLogInUsingaConsolePortConnectionprocedure
toaccessthemodulemanagementstartupscreenfromyourPC,terminal,ormodem
connection.
First-Time Log-In Using a Console Port Connection
Modem Port Adapter Wiring and Signal Diagram
RJ45 DB25
Pin Conductor Pin Signal
1 Blue 2 Transmit (TX)
2 Orange 8 Data Carrier Detect (DCD)
4 Red 3 Receive
5 Green 7 Ground (GRD)
6 Yellow 20 Data Terminal Ready (DTR)
8 Gray 22 Ring Indicator
RJ45 Connector (Female)
81
Pins
DB25 Connector (Male)
131
Pins
14 25
Note: This procedure applies only to initial log-in, and to logging in to a device not yet configured
with administratively-supplied user and password settings.
By default, the Matrix DFE Series device is configured with three user login accounts: ro for Read-
Only access; rw for Read-Write access; and admin for super-user access to all modifiable
parameters. The default password is set to blank (press Enter). For information on changing these