  • C
    Christine OlsonSep 18, 2025
    What should I do if debris is causing a short between the test pins in my Enthermics Food Warmer?
    • C
      Charles WilkinsonSep 22, 2025
      Ensure that debris is not causing a short between the test pins in your Enthermics Food Warmer. If the pins are good, replace the control.
  • J
    Jose JohnsonAug 25, 2025
    What to do if my Enthermics Warming Drawer displays error E-11?
    • T
      Terry YoderAug 25, 2025
      If your Enthermics Warming Drawer shows error code E-11, ES11, ES21, ES31, ES41, ES51, ES61, or ES71, this means the sensor is open. Start by pressing the ON/OFF button to acknowledge the error. If it continues, a qualified technician needs to test the sensor. This involves detaching the sensor and using an Ohm meter to measure its resistance in ice water at 0°C (32°F). A reading of 32.6 KOhm ±1.5 KOhm suggests replacing the display. If the reading is ±2 KOhm, replace the sensor. Check the wires and connections for any issues. If the problem remains, contact service.
  • D
    Diamond MartinezAug 26, 2025
    What to do if my Enthermics Warming Drawer displays error P130?
    • G
      gdonaldsonAug 26, 2025
      If your Enthermics Warming Drawer displays error code P130, P230, P330, P430, P530, P630, or P730, it means the heating pad hasn't reached the set temperature. First, acknowledge the error by pressing the ON/OFF button. If the error persists, a qualified technician should test the heater pad(s). Turn the unit OFF, unplug it, and use an Ohm meter to measure the resistance between the L (Line) and N (Neutral) leads of a cold heater pad. The Ohm readings should be 72 Ohm ±10% for 120V or 288 Ohm ±10% for 230V. If problems persist, contact service.
  • K
    kbrewerAug 26, 2025
    What to do if my Enthermics Warming Drawer displays error P131?
    • H
      Holly AustinAug 27, 2025
      If your Enthermics Warming Drawer displays error code P131, P231, P331, P431, P531, P631, or P731, it indicates a heater pad over-temperature error. The software will disengage the heating pads. Acknowledge the error by pressing the ON/OFF button. Allow the unit to cool down. If the error continues, contact service.
  • R
    Robert FitzgeraldSep 23, 2025
    What to do if the Enthermics Designer timer overlay is present, but no real time clock is detected?
    • P
      Paul RichardsSep 23, 2025
      If the timer overlay is present, but no real time clock is detected on your Enthermics Food Warmer, contact service.
  • G
    gilbertjordanSep 23, 2025
    What to do if the real time clock is not responding on my Enthermics Food Warmer?
    • A
      Andre WilliamsSep 23, 2025
      If the real time clock is not responding on your Enthermics Food Warmer, contact service.
  • B
    Brian VangSep 10, 2025
    What to do if the sensor reading is above the maximum allowable temperature set-point and over temp value in my Enthermics Food Warmer?
    • E
      Emily BoydSep 12, 2025
      If the sensor reading on your Enthermics Food Warmer is above the maximum allowable temperature set-point and over temp value, contact service.
  • C
    Christopher GarciaSep 12, 2025
    What should I do if my Enthermics Designer displays 'More heater pads detected than set for'?
    • K
      Katherine MorrisonSep 12, 2025
      If your Enthermics Food Warmer displays 'More heater pads detected than set for', hold the On/Off button for 12 seconds until the display shows "PAd#” (# = number of pads selected [3-7]). Then, press the up or down arrow to adjust to the correct number of pads.
  • G
    gravesjohnSep 3, 2025
    What does error E-31 mean on my Enthermics Warming Drawer?
    • E
      Evelyn WebbSep 4, 2025
      If your Enthermics Warming Drawer displays error E-31, it indicates that the sensor reading is above the maximum allowable temperature set-point. Contact service.
  • B
    Beth TownsendSep 1, 2025
    How to resolve error code E-70 on my Enthermics Warming Drawer?
    • J
      Jason WatsonSep 1, 2025
      If your Enthermics Warming Drawer displays error code E-70, it means more heater pads are detected than set for. Hold the ON/OFF button for 12 seconds until the display shows "PAd#" (# = number of pads selected [3-7]). Use the UP or DOWN arrow to adjust to the correct number of pads.