Operators Manual
Titan & Comfort Series
Blanket Warmer
EC250
EC350
EC400
EC750
DC250
DC350
DC400
DC750
MN-39924
REV.04
8/20
EN

Other manuals for Enthermics DC400

Questions and Answers

  • K
    Kyle MitchellSep 19, 2025
    What should I do if debris is causing a short between the test pins in my Enthermics DC400 Food Warmer?
    • F
      fordbrianaSep 22, 2025
      Ensure that debris is not causing a short between the test pins in your Enthermics Food Warmer. If the pins are good, replace the control.
  • E
    Elizabeth MoranAug 25, 2025
    What to do if my Enthermics Warming Drawer displays error E-11?
    • A
      Amber BoydAug 25, 2025
      If your Enthermics Warming Drawer shows error code E-11, ES11, ES21, ES31, ES41, ES51, ES61, or ES71, this means the sensor is open. Start by pressing the ON/OFF button to acknowledge the error. If it continues, a qualified technician needs to test the sensor. This involves detaching the sensor and using an Ohm meter to measure its resistance in ice water at 0°C (32°F). A reading of 32.6 KOhm ±1.5 KOhm suggests replacing the display. If the reading is ±2 KOhm, replace the sensor. Check the wires and connections for any issues. If the problem remains, contact service.
  • D
    doylethomasAug 25, 2025
    What to do if my Enthermics Warming Drawer displays error P130?
    • B
      beth53Aug 26, 2025
      If your Enthermics Warming Drawer displays error code P130, P230, P330, P430, P530, P630, or P730, it means the heating pad hasn't reached the set temperature. First, acknowledge the error by pressing the ON/OFF button. If the error persists, a qualified technician should test the heater pad(s). Turn the unit OFF, unplug it, and use an Ohm meter to measure the resistance between the L (Line) and N (Neutral) leads of a cold heater pad. The Ohm readings should be 72 Ohm ±10% for 120V or 288 Ohm ±10% for 230V. If problems persist, contact service.
  • J
    Jeremy Jackson MDAug 27, 2025
    What to do if my Enthermics Warming Drawer displays error P131?
    • D
      danielallenAug 27, 2025
      If your Enthermics Warming Drawer displays error code P131, P231, P331, P431, P531, P631, or P731, it indicates a heater pad over-temperature error. The software will disengage the heating pads. Acknowledge the error by pressing the ON/OFF button. Allow the unit to cool down. If the error continues, contact service.
  • B
    Bethany ReidSep 23, 2025
    What to do if the Enthermics Food Warmer timer overlay is present, but no real time clock is detected?
    • L
      lisawagnerSep 23, 2025
      If the timer overlay is present, but no real time clock is detected on your Enthermics Food Warmer, contact service.
  • I
    inguyenSep 23, 2025
    What to do if the real time clock is not responding on my Enthermics Food Warmer?
    • K
      kimberly22Sep 23, 2025
      If the real time clock is not responding on your Enthermics Food Warmer, contact service.
  • T
    Travis KaufmanSep 10, 2025
    What to do if the sensor reading is above the maximum allowable temperature set-point and over temp value in my Enthermics Food Warmer?
    • B
      Brian BrownSep 10, 2025
      If the sensor reading on your Enthermics Food Warmer is above the maximum allowable temperature set-point and over temp value, contact service.
  • G
    garnerkennethSep 12, 2025
    What should I do if my Enthermics Food Warmer displays 'More heater pads detected than set for'?
    • S
      Sandra CaldwellSep 12, 2025
      If your Enthermics Food Warmer displays 'More heater pads detected than set for', hold the On/Off button for 12 seconds until the display shows "PAd#” (# = number of pads selected [3-7]). Then, press the up or down arrow to adjust to the correct number of pads.
  • T
    Tanya EdwardsSep 4, 2025
    What does error E-31 mean on my Enthermics Warming Drawer?
    • L
      Lisa JosephSep 4, 2025
      If your Enthermics Warming Drawer displays error E-31, it indicates that the sensor reading is above the maximum allowable temperature set-point. Contact service.
  • A
    Abigail WilsonSep 1, 2025
    How to resolve error code E-70 on my Enthermics Warming Drawer?
    • T
      Theresa BaileySep 1, 2025
      If your Enthermics Warming Drawer displays error code E-70, it means more heater pads are detected than set for. Hold the ON/OFF button for 12 seconds until the display shows "PAd#" (# = number of pads selected [3-7]). Use the UP or DOWN arrow to adjust to the correct number of pads.

Summary

SAFETY

The Meaning of Signal Words

Explanation of hazard alert symbols (Danger, Warning, Caution, Notice, Note).

Safety Precautions

General safety guidelines to follow during operation and maintenance.

Operator qualifications

Required qualifications and training for personnel using the warmer.

Condition of warmer

Criteria that must be met for the warmer to be used safely.

Servicing the warmer

Guidelines for qualified personnel regarding warmer repair and service.

Incident notice

Procedure for reporting serious incidents involving the warmer.

LABELS

SPECIFICATIONS

INSTALLATION

OPERATION

Preparing the Warmer for First Use

Initial cleaning and checks before the first operation.

MAINTENANCE

TROUBLESHOOTING

What to do if a Power Interruption Occurs

Steps to take after a power outage to resume operation.

What to do if the Alarm Indicator Light Flashes

Actions to take when an alarm condition is indicated by the light.

Error Codes

List of error codes, their meanings, and recommended actions for resolution.

How to Replace a Fuse

Procedure for safely replacing a blown fuse in the warmer.

ELECTRICAL INFORMATION

Enthermics DC400 Specifications

General IconGeneral
BrandEnthermics
ModelDC400
CategoryFood Warmer
LanguageEnglish

Related product manuals