Page 9
710232A
6/23(&2817(18) - The number of cycles during which the percent current increases
or decreases cycle by cycle to achieve a slope function (gradual increase or decrease in
current).
27+(5352*5$00$%/()81&7,216
,038/6(6 (13) - In multiple impulse welding this counter counts the number of
predetermined Heat Impulses. The duration of the Heat Count is determined by the Heat
Count Selector.
3(5&(17&855(17 (9) (Phase Shift) 0 to 99% (Adjustable in 1% RMS current steps)
NOTE: For operator convenience, the following mode and function selection codes are
printed on the upper left corner of the Control panel, adjacent to Push Button (1).
6/23(02'( (17) - The type of slope function is determined by the code programmed
into this function as follows:
CODE 00: NO SLOPE during WELD Time. SLOPE control inoperative.
CODE 01: UP SLOPE
CODE 02: DOWN SLOPE
&<&/(02'( (16) - The manner in which the control performs schedules is determined
by the code programmed into this function as follows:
NOTE: For operator convenience, the following mode and function selection codes are
printed on the lower left corner of the Control panel, adjacent to Push Button (26).
CODE 00: NON-REPEAT MODE. In NON-REPEAT mode the control can be
initiated for only one sequence.
CODE 01: REPEAT MODE. In REPEAT mode, after initiation, the control
internally re-initiates as long as the initiation switch is maintained closed.
CODE 02: CHAINED MODE. In the CHAINED mode several schedules can be
"chained" together so that several consecutive schedules can be sequenced from one
initiation.
CODE 03: SUCCESSIVE MODE. In the SUCCESSIVE mode several schedules can
be sequenced successively upon separate initiation.