(5525&2'(6
Please refer to other manual pages and wiring diagrams for location of fuses, terminal strips, etc.
Please refer to Wiring & Logic Diagrams for Bills of Material.
7528%/(
3266,%/(&$86(
5(0('<
___________________________________________________________________________________
Data/Schedule Display
E.r. 01.
---------------------------
Data/Schedule Display
E.r. 02.
---------------------------
Data/Schedule Display
E.r. 03.
---------------------------
Data/Schedule Display
E.r. 04.
---------------------------
Data/Schedule Display
E.r. 05.
---------------------------
Data/Schedule Display
E.r. 06.
---------------------------
Data/Schedule Display
E.r. 07.
---------------------------
Data/Schedule Display
E.r. 08.
---------------------------
Data/Schedule Display
E.r. 09.
---------------------------
Data/Schedule Display
E.r. 10.
---------------------------
Data/Schedule Display
E.r. 11.
---------------------------
Data/Schedule Display
E.r. 12.
---------------------------
Data/Schedule Display
E.r. 13.
---------------------------
Data/Schedule Display
E.r. 14.
---------------------------
Data/Schedule Display
E.r. 15.
---------------------------
Data/Schedule
Display E.r. 26.
---------------------------
Data/Schedule Display
E.r. 27.
---------------------------
3.
Error Code #01. Temp. Limit
Sw. Open/Overheated.
--------------------------------------------
1.
Error Code #02. FS1 AND FS7
both closed.
--------------------------------------------
I.
Error Code #03. FS1 AND FS11
both closed.
--------------------------------------------
I.
Error Code #04. Attempt to weld
while in Program Mode.
--------------------------------------------
I.
Error Code #05.
FS1,FS3,FS7,FS11, closed to
GND before power on or before
Emergency Stop is re-closed
after being opened.
--------------------------------------------
I.
Error Code #06. Backstep or
Retraction is closed too long or
at start of sequence.
--------------------------------------------
I.
Error Code #07. FS1 initiated
while another seq. active.
--------------------------------------------
I.
Error Code #08. FS3 initiated
while another seq. active.
--------------------------------------------
I.
Error Code #09. FS7 initiated
while another seq. active.
--------------------------------------------
I.
Error Code #10. FS11 initiated
while another seq. active.
--------------------------------------------
I.
Error Code #11. Control BD.
Control Relay problem.
--------------------------------------------
I.
Error Code #12. Control BD.
Hardware error.
--------------------------------------------
I.
Error Code #13. Full conduction
detected. Man. PF. only.
--------------------------------------------
I.
Error Code #14. EEROM error.
--------------------------------------------
I.
Error Code #15. Pressure switch
open too long.
--------------------------------------------
I.
Error Code #26. Contactor short
detected.
--------------------------------------------
I.
Error Code #27. Retraction valve
is not on.
--------------------------------------------
1.
Wait for the Temperature Limit
Switch to cool, or Check for open
circuit .
--------------------------------------------
1.
Two Stage Operation not allowed
with FS7.
--------------------------------------------
1.
Two Stage Operation not allowed
with FS11.
--------------------------------------------
1.
Return to Operate Mode.
--------------------------------------------
1.
Initiations must be open at power on
or after an Emergency Stop.
--------------------------------------------
1.
Open TS1-TLS1/AUX1.
--------------------------------------------
1.
Open TS1-FS1
--------------------------------------------
1.
Open TS1-FS3
--------------------------------------------
1.
Open TS1-FS7
--------------------------------------------
1.
Open TS1-FS11
--------------------------------------------
1.
Replace Control Board.
--------------------------------------------
1.
Replace Control Board.
--------------------------------------------
1.
Change to higher welding
transformer tap.
--------------------------------------------
1.
Clear all SCHED and E.F.
2.
Replace Control Board.
--------------------------------------------
1.
Close Pressure switch.
2.
Check wiring for open.
--------------------------------------------
1.
Check contactor for short.
2.
Check Firing Module 410318.
--------------------------------------------
1.
Turn on retraction valve via
TS1-TLS1/AUX1.
--------------------------------------------

Other manuals for Entron EN1000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Entron EN1000 series and is the answer not in the manual?

Entron EN1000 series Specifications

General IconGeneral
BrandEntron
ModelEN1000 series
CategoryController
LanguageEnglish

Related product manuals