B Y : S H E R W O O D I N D U S T R I E S L T D
OWNERS MANUAL
EG31-118
FOCUS
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certied kit is used.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any
open ame.
• Do not try to light any appliance.
• Do not touch any electrical switch
or use any phone in your building.
• Immediately call your gas supplier
from a neighbours phone. Follow
the gas suppliers instructions.
• If you cannot reach your gas
supplier, call the re department.
WARNING: If the information in this manual is not followed exactly, a re or explosion may
result causing property damage, personal injury or loss of life. Installation and service must
be performed by a qualied installer, service agency or the gas supplier.
FOR YOUR SAFETY: Do not store
or use gasoline or other ammable
vapours and liquids in the vicinity of
this or any other appliance.
Massachusetts installations (Warning): This product must be installed by a licensed
plumber or gas tter when installed within the Commonwealth of Massachusetts. Other
Massachusetts code requirements: Flexible connector must not be longer than 36in., a
shut off valve must be installed; only direct vent sealed combustion products are approved
for bedrooms/bathrooms. A carbon monoxide detector is required in all rooms containing
gas red direct vent appliances. The replace damper must be removed or welded in the
open position prior to installation of a replace insert.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

Questions and Answers

  • K
    Kendra CruzAug 19, 2025
    What to do if main burner does not ignite in my Enviro FOCUS Indoor Fireplace?
    • J
      Jennifer PierceSep 12, 2025
      If the main burner on your Enviro Indoor Fireplace fails to ignite, first, ensure the gas control knob is in the “ON” position. If the thermostat isn't calling for heat, adjust it several degrees above the room temperature. If the issue persists, there may be a problem with the gas valve. Use a DC voltmeter to measure the voltage across the TPTH and TP terminals. The main operator voltage should be Open circuit ? 325mV, Closed circuit ? 100mV. If voltage isn't present, check the control circuit. If the correct voltage is present, consider replacing the gas control.
  • W
    wcookAug 21, 2025
    Why won't my Enviro FOCUS Indoor Fireplace burners remain lit?
    • S
      Shirley WarrenAug 21, 2025
      If the burners on your Enviro Indoor Fireplace won't stay lit, it could be a problem with the thermopile circuit. Check the gas line pressure and ensure there's proper flame impingement on the thermopile, referring to the 'Pilot will not remain lit' section if needed. Verify the thermopile reads a minimum of 300 mV when the burner is on. Also, inspect the thermostat wiring for any breaks. For BV models only, check for spillage at the draft hood that may trip the spill switch.
  • D
    David GatesAug 23, 2025
    What to do if spark will not light the pilot in my Enviro Indoor Fireplace?
    • J
      Jennifer FrancoAug 25, 2025
      If the spark isn't lighting the pilot on your Enviro Indoor Fireplace after repeatedly pressing the spark ignitor, check the connections to the ignitor. If connections are good but there's still no spark, replace the ignitor. Also, inspect the spark electrode for broken ceramic insulation; replace the electrode if it's broken. If the spark isn't arcing from the electrode to the pilot, loosen the screws on the pilot base, adjust, and then tighten them.
  • C
    carmenboothAug 26, 2025
    Why does my Enviro FOCUS flame lift?
    • S
      stephen41Aug 26, 2025
      Flame lifting in your Enviro Indoor Fireplace can be caused by a leak in the vent pipe, so check for leaks in vent connections. It may also be due to an improper vent configuration, so check the vent configuration against the manual. Another potential cause is the terminal recirculating flue gases; ensure the terminal is installed correctly and consider installing a high wind termination cap. Contact your dealer for assistance.
  • D
    Daniel LutzAug 28, 2025
    What to do if pilot will not remain lit on my Enviro FOCUS Indoor Fireplace?
    • M
      monica76Aug 28, 2025
      If the pilot light on your Enviro Indoor Fireplace won't stay lit, first check the thermocouple connection at the rear of the valve, ensuring it's fully tightened. Verify the pilot flame fully impinges on the thermocouple; if the flame is too small, check the gas pressure, adjust the pilot rate screw, and inspect the pilot head for damage. Check the thermocouple voltage at the valve; it must be greater than 5 mV. If low, replace the thermocouple. Air in the gas line can also cause this issue, so bleed the line and check gas line pressure. Contact your dealer for assistance.
  • R
    Renee GainesAug 30, 2025
    Why are the flames burning dirty in my Enviro FOCUS?
    • B
      Blake MurphyAug 30, 2025
      If the flames in your Enviro Indoor Fireplace are burning 'dirty' or sooting, check the log positioning to ensure there is no flame impingement. Increase primary air by opening the venturi shutter and/or by opening the vent restrictor. You may also need to refer to the 'Burners will not remain lit' section for additional troubleshooting steps.
  • D
    Dale PatelSep 1, 2025
    Why is my Enviro FOCUS Indoor Fireplace remote control not working?
    • J
      Jason HernandezSep 1, 2025
      If your Enviro Indoor Fireplace remote control isn’t working, start by checking the batteries in the remote, following the remote control instructions. If the remote is not the issue, ensure the on/off switch on the fireplace is turned to ON, the gas control valve is not set to PILOT or OFF, and that the pilot light is lit.
  • M
    melindaramirezSep 3, 2025
    Why Enviro Indoor Fireplace BV ONLY has insufficient air for combustion?
    • T
      Taylor SimsSep 3, 2025
      If your BV ONLY Enviro Indoor Fireplace has insufficient air for combustion, it may be due to an air-tight house or a vacuum in the room caused by another air-moving device. Supply make-up air to the unit.
  • J
    James HenrySep 5, 2025
    Why won't the main burner ignite on my Enviro Indoor Fireplace?
    • D
      Dennis MarquezSep 5, 2025
      If the main burner of your Enviro Indoor Fireplace doesn't ignite, first, ensure the gas control knob is in the “ON” position. If it still doesn't ignite, check if the thermostat is calling for heat by adjusting it several degrees above the room temperature. If these steps don't work, there may be an issue with the gas valve. Use a DC voltmeter to measure the voltage across the TPTH and TP terminals. The main operator voltage should be: Open circuit ? 325mV, Closed circuit ? 100mV. If the voltage isn't present, check the control circuit. If the voltage is correct, you may need to replace the gas control.
  • J
    jessicawagnerSep 7, 2025
    What to do if my Enviro Indoor Fireplace remote control doesn't work?
    • M
      Marie DouglasSep 7, 2025
      If the remote control for your Enviro Indoor Fireplace isn't working, start by checking the batteries in the remote and refer to the remote control instructions for replacement. Also, ensure the on/off switch on the fireplace is turned to ON, the gas control valve is not set to PILOT or OFF, and that the pilot light is lit.

Summary

Safety Precautions

General Safety Guidelines

General installation and safety guidelines for the appliance, emphasizing qualified personnel and proper placement.

Operational Safety Instructions

Specific safety instructions for operation, including warnings about children, flammables, and usage.

Codes And Approvals

Specifications

Dimensions

Provides detailed exterior dimensions of the fireplace unit with diagrams and measurements.

Operating Instructions

Lighting Instructions

Step-by-step guide for safely lighting the fireplace pilot and main burners, including safety checks.

Maintenance And Service

Fuel Conversion Process

Instructions for converting the appliance between Natural Gas (NG) and Propane (LP) fuels.

Initial Installation

Clearances to Combustibles

Specifies minimum safe distances from the appliance to flammable materials.

Electrical Requirements and Wiring

Information on electrical connections, wiring diagrams, and grounding for the appliance.

Gas Line Connection and Testing

Procedures for safely connecting the gas supply line, including pressure testing and leak checks.

Secondary Installation

Trouble Shooting

Parts List - Components

Warranty Information

Limited Lifetime Warranty

Covers fireplace body and accessories against defects for 7 years (parts) and 2 years (labor).

Warranty Exclusions and Limitations

Lists conditions not covered by the warranty, including installation, misuse, and normal wear.