INSTALLATION, OPERATION & MAINTENANCE
HORIZONTAL, LOW PROFILE FAN COILS
Series D
Supersedes ET115.24-NOM11 (417)
Form ET115.24-NOM11 (118)

Table of Contents

Questions and Answers:

Enviro Series D Specifications

General IconGeneral
BrandEnviro
ModelSeries D
CategoryFan
LanguageEnglish

Summary

Safety Symbols and Precautions

Safety Symbols Definitions

Explains the meaning of DANGER, WARNING, CAUTION, and NOTE symbols used in the manual.

Electrical Shock Hazard Precautions

Emphasizes disconnecting all power sources before installation or servicing.

Moving Parts Hazard Precautions

Advises disconnecting power and control circuits before servicing.

Hot Parts Hazard Precautions

Stresses disconnecting power before servicing heating elements.

Rigging and Lifting Safety

Details safe practices for supporting and securing units during lifting.

Brazing and Fire Safety

Advises on protecting flammable materials and having fire extinguishers ready.

Section One: Receipt & Initial Installation

HL Series Features

Overview of the features of the HL Series fan coil units.

Preface and Manual Overview

Introduction to the fan coil unit manual and its purpose.

Unpacking and Inspection Procedures

Guidelines for inspecting units upon receipt to check for damage or discrepancies.

Handling and Installation Guidelines

Instructions for safely moving, positioning, and installing the unit.

Code Compliance

Information on meeting UL and CSA standards for heating and cooling equipment.

Typical Ceiling Installation

Illustrates a standard method for installing the unit in a ceiling.

Drain Pan and Coil Details

Information on drain pan removal and coil configurations for heating and cooling.

Cooling/Heating Medium Connections

Guidance on connecting chilled/hot water or refrigerant lines to the unit.

Auxiliary Drain Pans and Ductwork

Details on installing auxiliary drain pans and connecting ductwork to the unit.

Electrical Connections and Enclosure

Guidance on making electrical connections and accessing the enclosure.

Telescoping Bottom Panel Installation

Instructions for installing and adjusting the telescoping bottom panel.

Service and Clearance Requirements

Exposed Unit Clearances

Diagrams showing required clearances for exposed horizontal fan coil units.

Height Restricted Application Clearances

Clearances required for installations with height limitations.

Width Restricted Application Clearances

Clearances needed for installations with width restrictions.

External Space Requirements

Notes on clearances for access to control enclosures and piping.

Section Two: Start-Up

General Start-Up Procedures

Initial steps and checks before starting the unit operation.

Cooling/Heating System Start-Up

Procedures for filling and venting water systems.

Air System Balancing

Steps to balance airflow and establish system operating conditions.

Section Three: Normal Operation & Periodic Maintenance

General Maintenance Guidelines

Advice on establishing maintenance schedules and logs for units.

Motor/Blower Assembly Care

Instructions for servicing and cleaning the motor and blower assembly.

Coil Cleaning Procedures

Methods for cleaning heating and cooling coils to maintain performance.

Electrical Wiring and Controls Maintenance

Checks and maintenance for electrical connections and control components.

Valves and Piping Maintenance

Guidance on inspecting valve packages and piping for leaks.

Filter Replacement

Guidance on replacing throwaway filters on a regular basis.

Section Four: Inspection & Start-Up Checklist

Receiving and Inspection Checklist

Items to check upon unit receipt for damage and correctness.

Handling and Installation Checklist

Checks for proper mounting, service, and code compliance during installation.

Cooling/Heating Connections Checklist

Verification of piping, valve packages, and insulation during installation.

Ductwork Connections Checklist

Checks for proper ductwork, grilles, and freeze protection.

Electrical Connections Checklist

Verification of wiring diagrams and field wiring compliance.

Unit Startup Checklist

Final checks before energizing the unit, including voltage and connections.

Section Five: Fan Relay Board

FRBii Installation and Operation

Details on installing, operating, and maintaining the Fan Relay Board.

FRBii Wiring and Ratings

Information on wiring, voltage, and temperature ratings for the FRBii.

FRBii Inputs and Outputs

Identification of terminal block signals and connector layouts.

Section Six: Troubleshooting

Fan Relay Board Troubleshooting

Common issues and corrective actions for the fan relay board.

PSC Motor Troubleshooting

Diagnosing and resolving problems with PSC motors.

EC Motor Troubleshooting

Diagnosing and resolving problems with EC motors.

Cooling System Troubleshooting

Identifying and fixing issues related to insufficient cooling or unit sweats.

Electric Heater Troubleshooting

Troubleshooting electric heat operation, overheating, and insufficient heating.