AFTER INSTALLATION THE END USER SHOULD
KEEP THIS GUIDE FOR FUTURE REFERENCE
DO NOT
THROW AWAY
8
In conditions between 19°C - 25°C the units will increase air flow rate
by 10%. In hot conditions above 25°C the units will temporarily switch
off to avoid bringing hot air into the property from the loft space.
The ATMOS unit uses a single 200mm diffuser to provide air into a
hallway or landing area.
The ATMOS DUAL unit uses two 100mm diffusers to provide airflow
to separate locations within the building. It is normally required for
applications where:
a) The hallway is small.
b) Limited heating is available.
c) The loft hatch fills the hallway ceiling.
d) Airflow is required in a remote area such as a bedroom.
Option 1
If a higher airflow is required in the hallway, position
that diffuser a shorter distance from the unit.
Other room
(lower flow rate)
Hallway
(higher flow rate)
Option 2
If a similar airflow is required in the hallway, position
both diffusers at similar distances from the unit.
Other room
(similar flow rate)
Hallway
(similar flow rate)