CLASSIC-100 AXIAL EXTRACTOR FANS
Suitable for bathroom applications
INSTALLATION
IMPORTANT: before installing and wiring the unit, ensure that the mains supply is
disconnected.
CLASSIC-100 sh ould only be used in conju nction with fixed wiring.
Fig.1 1 – Grille
2 – Cable entry point
3 – Connection cover
4 – Fixing screw
5 – Connection termin als
6 – Outlet
7 – Slot
The CLASSIC-100 is suitable for wall, ceiling or window (using the CLASSIC-100 window
kit) i nstallations.
Panel M odel
Drill a 105mm-diameter hole in chosen position in the panel surface.
Loosen the screw (4), which holds the grille in place (1) and remove grille.
Mark the fixing holes in the back of the fan plate. This fan must be installed by a
competent person. Complete electrical wiring of fan as outlined in the Wiring
Instructions o verleaf. Then refit the grille and tighten the screw (4).
Bind the adhesive tape supplied around the outlet (6).
Wall Model
Drill a 115mm d iameter hole in chosen position through the wall. Slope the wall
slee ve downwards to prevent rainwater running through the duct into the unit. The
end with the larger diameter should be on the room side.
Loosen the screw (4), which holds the grille in place (1) and remove grille.
Mark the 4 screw hole positions. Drill, plug and screw into position. Repeat this
process for the external grille sub-
frame. Fix the exterior grille in position, whilst
ensu ring that the louvres are positioned downwards.
Check t hat the wall tube is not distorted and that the impeller turns freely.
This fan must be installed by a competent person. Complete electrical wiring of fan as
outlined i n the Wiring Instructions below. Then refit the grille and tighten the screw (2).
Bind the adhesive tape supplied around the outlet (6).
•
•
•
•
•
•
•
•
•
•