EasyManua.ls Logo

EONE GCM-X - Specifications; Measurement Characteristics; Electrical Characteristics

Default Icon
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
GA0383P02 Rev. C
Specifications
Measurement Characteristics
Detection principle Submicron particle detector
Air Flow Rate Adjusted by Zone Manifold, nominal 14 LPM
Readout (bar graph) Ambient Air 0% to 100% of scale
Generator Air 0% to 100% of scale
Electrical Characteristics
Power Input, grounded power cable 115/230 VAC, 50/60 Hz
Output Relays, general purpose
Ambient Alarm, Generator Alarm,
Differential Alarm, Common Warning,
System Trouble, Flow Trouble 120 VAC/28VDC / 3.0 A
Output Signal (4-20 mA)
Ambient Air 0% to 100% of scale
Generator Air 0% to 100% of scale
Mechanical Characteristics
Dimensions, overall 24” H x 22” W x 9 1/8” D*
(610 mm x 559 mm x 232** mm)
Weight, approximate 88 lbs. (40 kg)
Connectors, gas inlet 3/8” NPT, female
Temperature, maximum 32-122 F (0-50 C)
Area Classification CE, Non Hazardous
Relative Humidity 0-95%
Controls 5-key membrane switch keypad with liquid
crystal display
* 8”/203 mm for GD0080G02
** 10”/254 mm for GD0080G01

Table of Contents