113
NOTES
¹
Rating conditions: Indoor: D.B. 80ºF, W.B. 67ºF; Outdoor: D.B. 95ºF, W.B. 75ºF.
²
Minimum capacity.
³
Maximum capacity including 2,400 BTu/h boost mode, system is not designed to run on max capacity on a continuous basis.
Design should be based on Rated Capacity
⁴
Rating conditions: Indoor: D.B. 70ºF, W.B. 60ºF; Outdoor: D.B. 47ºF, W.B. 43ºF.
⁵
Rating conditions: Indoor: D.B. 70ºF, W.B. 60ºF; Outdoor: D.B. 47ºF, W.B. 43ºF with supplemental 1 kw electric heat strip.
⁶
COP performance bases on reverse cycle heat pump only. ³
⁷
Rating conditions Indoor: D.B. 70ºF, W.B. 60ºF; Outdoor: D.B. 17º F, W.B. 15º F.
⁸
Rating conditions Indoor: D.B. 70ºF, W.B. 60ºF; Outdoor: D.B. 17º F, W.B. 15º F with supplemental 1 kw electric heat strip.
⁹
All units require a Leak Current Detector Interrupter (LCDI) power cord unless hardwired with a dedicated breaker to UL 484
standards.
¹⁰
LDCI power cord must be specified when ordering.
¹¹
MCA ratings conform to National Electric Code; however, local codes should apply. For models with electric heat, the amps
includes the electric heat strip of 1 kW.
¹²
Conforms with National Electrical Code 440.62 to allow H2P815XXXX on a 15A branch circuit where lighting outlets, other
appliances, or general-use receptacles are supplied, as the total rating of the cord-and plug-connected H2P815XXXX (7.3A)
uses less than 50% of the 15A branch circuit.
¹³
Sound Pressure: When floor mounted, sound level is measured 39.4 in. from air-outlet in horizontal distance, 39.4 in. above the
floor in vertical distance. When high wall-mounted, sound level is measured 39.4 in. from air-outlet in horizontal distance, 39.4
in. from air-outlet in vertical distance.
¹⁴
Sound Pressure: Anechoic chamber conversion value, measured at a point 39.4 in. from the front of the unit at a height of 39.4
in. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
¹⁵
Must use approved grilles and sleeves.
¹⁶
Controller type must be specified when ordering the unit. Additionally, the wall touch-controller may be ordered as an
accessory. Only a single controller option will work at a time. Wall controller is wired.
¹⁷
On Auto mode, deadband is 7.2°F
¹⁸
This mode restricts the temperature setting to 71.5°F to 82.5°F in cooling mode and 61°F to 75°F in heating mode. It also dis-
ables dehumidification mode and automatic mode.
¹⁹
COOLING MODE: The fan is set to low and the temperature will automatically increase by 1.5°F after the first hour and then
by 1.5°F after the second hour. After eight hours, the HPAC 2.0 Air Conditioner will automatically turn off.
HEATING MODE: The fan is set to low and the temperature will automatically lower by 1.5°F after the first hour and then by
another 1.5°F after the second hour. After eight hours, the HPAC 2.0 Air Conditioner will automatically turn off.
²⁰
Must be specified when ordering unit, can not be field installed.
²¹
Warranty limited to installations in the United States only. See warranty documentation for full details.