16000 - X-Axis Replacement
3
7. Remove the le and right bellows
by loosening the six (6) 5/16” nuts and
backing plate:
8. Loosen, but do not remove the four
(4) Phillips screws that hold the x-axis
drive board cover:
9. Remove the x-axis drive board cover.
10. Disconnect the seven (7) electrical
connectors from the drive board:
11. Disconnect the air tubing from the
elbow connector at right side of the
x-axis assembly:
The air tubing is held by a retaining fix-
ture. To remove the tubing, press the
tubing into the fixture. Then, while holding
the orange retaining ring tight to the fix-
ture pull the air tubing away from it.
12. Loosen and remove the four (4) 7/64
hex screws that hold the x-axis drive
board housing:
13.