56
DIP Switch Bank 2
SW Function ON OFF
Default
setting
2-1 Handshaking (BUSY condition) Receive buffer full
Offline
Receive buffer full
OFF
2-2 Reserved (Do not change setting) Fixed to OFF OFF
2-3
2-4
Selects print density
See "Selecting the Print Density (DIP Switches 2-3/
2-4)" on page 58
.
OFF
2-5
Sets the release condition of the
receive buffer BUSY state. (The
reception buffer capacity is effective
when set to 4 KB.)
Releases the BUSY state
when the remaining
capacity of the receive
buffer reaches 138 bytes.
Releases the BUSY state
when the remaining
capacity of the receive
buffer reaches 256 bytes.
OFF
2-6 Reserved (Do not change setting) Fixed to OFF OFF
2-7 I/F pin 6 reset signal Enabled Disabled OFF
2-8 IF pin 25 reset signal Enabled Disabled OFF
For DIP Switch 2-1 (BUSY condition), see also
"Selecting the BUSY Status" on page 58.
When you use the APD, change the setting of DIP switch 2-1 (BUSY condition) to ON.