EasyManua.ls Logo

Epson Pro L12000QNL - Page 164

Epson Pro L12000QNL
299 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
164
2. Select the Reset menu and press Enter.
You see a screen like this:
3. Select Light Source Calibration and press Enter.
4. Select any of the following:
To run the light source calibration now, select Run Now.
To automatically run the light source calibration every 100 hours of projector usage, select Run
Periodically.
To schedule automatic calibration, select Schedule Settings.
Last Run displays the last time the projector performed a calibration.
Note: If you use the projector continuously for more than 24 hours or use direct shutdown regularly,
select Schedule Settings to schedule calibration of the light source periodically.
5. When you are finished, select Return and press the Enter button to return to the Reset menu.
Parent topic: Using Advanced Image Adjustment Features
Related tasks
Turning On the Projector
Turning Off the Projector
Stopping Video Action Temporarily

Table of Contents

Related product manuals