10. Select the area of the screen that you want to adjust and press Enter.
Note: Adjust the outer areas first, then adjust the entire screen.
11. Select the color (Red, Green, or Blue) you want to adjust, and use the left arrow button to weaken
the color tone and the right arrow button to strengthen the color tone.
12. Press Esc.
13. Repeat steps 10 and 11 for each area you want to adjust.
14. Repeat steps 7 to 11 for each adjustment level.
15. When you are finished, press the Menu button.
Parent topic: Using Advanced Image Adjustment Features
Running Light Source Calibration
Light source calibration automatically adjusts any difference between the white balance and the
brightness level of the light source. You should perform light source calibration every 100 hours of
projector usage. You can also schedule automatic calibration or run the light source calibration manually
using the menus.
Automatic light source calibration may not start in the following conditions:
Within 30 minutes of turning on the projector.
When using the Shutter feature or within 30 minutes of releasing the shutter.
When using direct power shutdown.
When you have used the projector continuously for over 24 hours.
Note: To perform a light source calibration, the projector must have been on for at least 30 minutes and
the projector brightness must not be automatically dimmed due to high temperatures.
1. Press the Menu button.