EPSON Stylus Photo R340/350 Revision A
Adjustment Adjustment Except Adjustment Program 108
3.3 Adjustment Except Adjustment Program
Following is adjustment except Adjustment Program.
3.3.1 PG Adjustment
[Purpose]
This adjustment is required when removing or replacing the following parts/units in
order to secure the specified space between the print-side of the Print Head and the
paper.
Carriage Unit
CR Guide Shaft
Left (Right) Parallel Adjust Bushing
(Including when having moved the Left (Right) Parallel Adjust Bushing)
[Adjustment Procedure]
1. Make both sides of the two Thickness Gauge (1.30mm and 1.46mm) clean by
wiping with Bemcot with a little alcohol.
2. To make the PG position minus (-), turn the gear of the APG Assy. and match the
flag centre of the Right CR Cam with the PG Sensor.
Figure 3-6. Setting PG Position
3. Match the 0 position (Hole point of gear) of the Left (Right) Parallel Adjust
Bushing with the rib of the Main Frame.
Figure 3-7. Setting Parallel Adjust Bushing
4. Move the Carriage Unit to the centre of the printer and remove the Cartridge
Lever. Then, set the PG-Adjustment Dummy Cartridge.
Gear of the APG Assy.
Right CR Cam
PG Sensor
Flag
Left Parallel Adjust Bushing
Ribs
Hole point
Right Parallel Adjust Bushing
Ribs
Hole point

Table of Contents