Care & maintenance
WARNING! Always switch the product off, lock the trigger (15), disconnect
the product from the power supply and let the product cool down before
performing inspection, maintenance and cleaning work!
Clean
1. Clean the product with a dry cloth. Use a brush for areas that are hard to reach.
2. In particular clean the switches and air vents after every use with a cloth and brush.
3. Remove stubborn dust with high pressure air (max. 3 bar).
01
Cleaning of tubes (6, 7) (Fig. O)
NOTE: Do not use chemical, alkaline, abrasive or other aggressive
detergents or disinfectants to clean this product as they might be harmful
to its surfaces.
Clean the airless paint sprayer immediately after each use as detailed below. Also, if
the airless paint sprayer clogs up during use, carry out the same cleaning procedure.
1. Remove the prime tube (6) and the suction tube (7) from the paint pail.
2. Separate the prime tube (6) from the pipe clips (9) (Step 1).
3. Place and hold the prime tube (6) in waste bucket (Step 2).
4. Submerge the suction tube (7) in water or ushing solvent (step 3).
5. Turn the Prime/Spray lever (3) downward to the prime mode (Step 4).
6. Adjust the pressure control knob (22) at higher pressure setting (Step 5).
7. Connect to power supply and switch the airless paint sprayer on (Step 6).
8. Sprayer will start pumping and water or ushing solvent as well as air bubbles will
be purged from system. Let uids discharge from the prime tube (6) into waste
bucket until uid is clear.
MNL_Erbauer_GB_EAPS600_600W Airless Paint Sprayer_V1_201029.indd 38 10/29/20 3:31 PM