2.2.5 ELECTRICAL DATA
Machines must be connected to the power supply it was intended for by design.
Power supply:
Voltage Frequency Power Current
220V 50/60Hz 1000W 5A
110V 50/60Hz 1000W 10A
Table 2.2.3 – Supply Voltage
Insulation level: 1
Motor: electrical motor with double insulation in conformity with EC standards
Protection: protection system with fuses
Model Fuse
Voltage General Protection Electronic Circuit
220V 8A gG 315mA gG
110V 16A gG 630mA gG
Table2.2.4 – Protection Fuses
Motor overloading protection: automatic electronic blocking at 1000W on all models
2.2.6 DIMENSIONS AND WEIGHT
Machine body:
Machine body
Machine body without accessories 23Kg
Width 260mm
Length 600mm
Height 900mm
Table 2.2.5 – Dimensions and Weight
Maximum usable former weight: 10Kg
2.2.7 NOISE LEVEL
Emission values on working areas: 82dB(A)
EC DIR. 392/89 – I, 1, 7, 4, F
2.2.8 TECHNICAL NOTES
Machine design and technical specifications may be modified without advice.