EasyManuals Logo
Home>ergoline>Personal Care Products>ESSENCE 48 SMART POWER

ergoline ESSENCE 48 SMART POWER User Manual

ergoline ESSENCE 48 SMART POWER
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
Appendix
02/2021 1026110-00 Operating instructions – 53/58
6 Appendix
6.1 JK timer controls
The following coin modules/time control systems can be utilized with the ES-
SENCE series devices.
MCS III plus
Order no.: 500000456
Studiopilot
Order no.: 34009900
6.2 Equivalence key range
Example for calculating the equivalence key range (1), see the lamp
configuration sticker:
If the equivalence key of the lamp with which the device has been equipped
during the type approval is
100–R–47/3.2,
the equivalence key range with which the device should be marked is calcu-
lated as follows:
Bottom value of the X section: 0.75 x 47 = 35.25
Bottom value of the Y section: 0.85 x 3.2 = 2.72
Top value of the Y section: 1.15 x 3.2 = 3.68
X is rounded up to the next whole value, Y will be rounded to the first decimal
place after the point. The equivalence key range for fluorescent lamps is then: