8 C O O L I N
T E S C
Press ESC for going back to page 1
Adjustment of the run-on time. The fan run on time can be adjusted between 30 seconds and 5
minutes by the european version and between 3 minutes and 5 minutes by the US-Version.
The factory setting is 3 minutes.
Press ENTER for the next page:
8a C O O L I N
G : 0 3 0
Value 30 is blinking
< > M
O E S C
Press ESC for going back to page 8
Pressing < or > buttons you can modify the cooling value with steps of 30 seconds.
9 R E M
T E S C
Press ESC for going back to page 1
Adjustment of using a coin box or a studio control system.
Pressing ENT button the following page will appear:
9a R E M
A B
ENAB is blinking
< > M
O E S C
Press ESC for going back to page 9
Selecting < or > you can choose between ENAB and DISAB, that means the unit is controlled
by an external timer (remote control enabled) or by the internal one (disable):
9b R E M
I S A B
DISAB is blinking
< > M
O E S C
Press ESC for going back to page 9
Pressing MEMO button the chosen option is saved.
If the remote control function is enabled, the display will appear as the following page:
9c E R G O L I N
E
S T A R T
This page will come back after 3 minutes without pressing any button; pressing one of the 4
buttons the following page will appear:
9d L E F T
E 0 0 : 0 0
S T A R T E S C
Press ESC for going back to page 1
Pressing START button a free potential switch will be closed (start command), and this switch
will remain closed for 5 seconds and then will open again;