Trouble Shooting Guide, Advanced
4/00021-3/FEA 209 544/25 C
Ericsson Mobile Communications AB
18(78)
The result is for the two current levels are presented in hex, Fig. 6.5.
Fig. 6.5
The next window tells you to disconnect the DCIO, Fig. 6.6.
Fig. 6.6
The limits for the calibrations are displayed in the table below, Table. 6.1.
Selected charge
current
MIN MAX UNIT
100mA-ADC value
0A 29
HEX
10 41
DEC
100mA-DCIO current
45 193
mA
800mA-ADC value
99 BF
HEX
153 191
DEC
800mA-DCIO current
720 899
mA
Table. 6.1.