INSTALLATION INSTRUCTIONS
7 Power equipment
The TAU D is powered from the Extension line.
8 Earthing
The TAU D needs no special earthing.
9 Cabling
Maximum line length using DBC 200 series telephones and 0,5 mm EKKX cable:
1000m (3280 ft)
exemption: using a DBC 203 with 2 DBY 409 and 0,5 mm EKKX cable: 800m (2625 ft)
Maximum line length using DBC 600 series telephones and 0,5 mm EKKX cable:
1000m (3280 ft)
Recommended maximum cable length between:
TAU D and PC: 3,0m (9,8 ft)
The following cables are used:
- Telephone jack cable with modular RJ12 connector towards the TAU D
- Telephone cable with modular RJ12 connector in both ends to be used when a digital system
telephone shall be connected to the TAU D
- Standard 9 pole V.24/RS-232-C cable with a male connector towards the TAU D.
NOTE: Using TAU D together with DBC 600 series telephones connected to ELU 28 or
ELU 25/3 will in some configurations slightly exceed the maximum line current.
This will cause the TAU D and DBC 600 telephone not to start or work properly.