EasyManua.ls Logo

Ericsson BDV BS 101 01 - Page 24

Ericsson BDV BS 101 01
225 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25(46)
Date Rev
DocumentnumberPrepared
Doc respons/Approved Checked Reference
1998-05-29
L
1531-BDV BS 101 01 Uen
INSTALLATION INSTRUCTION
Subject responsible
wise data is lost if printer is OFF. The range of the in-
terface is up to 1200m.
Several converters may be used but with the following
successful tests were accomplished:
IC-485SI from ARP DATACON and
232<->485/422 Converter Plus IC-109AE from Black
Box Corp.
6.12.1 Feature Enabling Control Unit (FECU)
Connecting this plug activates the appropriate applica-
tions and features as ordered depending on the FECU
index number. If no plug is connected only a limited
Version 3.0 system functionality is available. The indi-
ces 2 to 10 always include the Basic Version 3 func-
tionality (index 1).
For detailed information of the features enabled by the
different FECUs refer to 15534-ASB 150 02 Uen
FACILITY DESCRIPTION GENERAL.
FECU number Functionality Version 3.1
KDU BS 130 06/1 Basic Version 3.0 functionality
KDU BS 130 06/2 + std. digital networking for max.
32 interfaces
KDU BS 130 06/3 + std. digital networking
KDU BS 130 06/4 + full. digital networking for max.
32 interfaces
KDU BS 130 06/5 + full. digital networking
KDU BS 130 06/6 + CTI
KDU BS 130 06/7 + CTI and std. digital networking
for max. 32 interfaces
KDU BS 130 06/8 + CTI and std. digital networking
KDU BS 130 06/9 + CTI + full. digital networking for
max. 32 interfaces
KDU BS 130 06/10 + CTI + full. digital networking for
unlimited number of interfaces

Table of Contents