7 | P a g e
INSTALLATION
The complete installation should consist the following items:
Description
Type
Quantity
1.
Welding Power Source
ARC400i
1
2.
Welding Cable with Holder
1
3.
Earth cable with Clamp
1
4.
Remote (Optional)
RT-ARC400i
1
CAUTIONS FOR INSTALLATION
Provide a Switch Box for every Welding Power Source, and use designated fuse
Tolerance of Power Voltage Variation is 10% of rated input voltage.
a) Installation place
Install in the place where less moisture and dust exist. Avoid direct sunlight and rain, and
maintain ambient temperature within 10
o
to +45
o
C as much as possible.
Keep the welding power source at least 20 cm. away from the wall (if any).
In case of installation of more two units side by side, a distance of more than 20 cm is
recommended between the two power sources.
Use a shield to protect the welding arc in case of excessive air draft.
b) Ventilation
Adequate ventilation is recommended at the place of installation. For example the
following guideline should be followed:
a) In case of the area being more than 300 square meters (per unit), no ventilation is
required, provided the room is not completely airtight.
b) In case of the area being less than 300 square meters and the welding is
continuously performed, adequate ventilation is recommended with the help of vent
fan or exhaust duct.
c) While performing the grounding work, it is recommended that a skilled electrician
does the work.