6. Auxiliary On/O Button
The fireplace has a manual On/O push button located on the bot-
tom right of the fire as shown, and is accessed without removing any
panels.
This button should be used if the wireless control becomes lost, dam-
aged, or its batteries are flat. Pushing the “AUX On/O” button once
will start the heater and it will run at a medium heat output setting
until the “AUX On/O” is pushed again to shut the heater down.
7. Over Temp Shuto Operation
By default Escea gas fires continue running at their lowest setting when the “Room” temperature has reached the
“Set” temperature. However, in some cases the output of the fire, at its lowest setting, may exceed that which is
needed to keep the room at a steady temperature and the “Room” temperature may continue climbing above the
“Set” temperature.
Your Escea gas fire has a setting where it will turn o the main burner once the “Room” temperature exceeds the
“Set” temperature, leaving only the pilot lit. The main burner will re-light when the “Room” temperature falls
back below the “Set” temperature. This is referred to as the “Overtemp Shut O Mode”.
To enable “Overtemp Shut O Mode”, so the fire will turn o the main burner when the “Room” temperature
climbs above the “Set” temperature, you need to follow the steps below to make the adjustment to your Escea
remote.
Step1: While the remote is in its “OFF” mode with only the time showing on the display, press the
MINUS (4), PLUS (8) and FAN BOOST (7) buttons simultaneously (as shown below right) until the
characters “03” light up on the display. Release the buttons and the remote will count down and
display “GO”. The screen will then display all characters. This will put the remote into test
mode and the two big temperature digits should begin counting from 0 to 99 repeatedly.
Step 2: Press the “TIMER SELECT” Button (5) and you will see that the
temperature digits stop counting and will momentarily display “ON” to
confirm the setting has been made.
Step 3: To exit the test mode press the ON/OFF button (2).
To turn OFF the “Over Temp Shut O Mode”, so the burners remain lit
when the “Room” temp reaches and goes above the “Set” temp, repeat
step 1.
Step 4: Press the “ACTIVATE TIMER” (9) Button and you will see that the
temperature digits stop counting and will momentarily display “OF” to
confirm the setting has been made.
Step 5: To exit the test mode press the ON/OFF button (2).