EN
8. POSSIBLE FAULTS, CAUSES AND SOLUTIONS
1) The motor does not start.
2) Motor operates but there is no pressure.
3) Motor over-heating.
4) Pump does not deliver rated capacity.
5) Motor starts and stops automatically.
6) Shaft rotates with difficulty.
9. TECHNICAL DATA
Liquid temperature… ............................. .4ºC - 40ºC
Ambient temperature: ............................. 0ºC - 40ºC
Storage temperature: ........................... -10ºC - 50ºC
Ambient relative humidity, max.: ...................... 95%
Motor class I.
Other data see Figure 2.
Disconnect it and take it to the official Technical
Service
Clean it or replaced by new one
Total head higher than expected
Verify geometric head and loss of head
Check that the tension is the same as that on the
name plate
Water level in well or tank has come
down
Fuse or thermal relay disconnected
Change fuse or thermal relay
Disconnect pump and take it to your Service
Dealer
Be sure suction pipe is submerged
Fill pump body with water
Seal unions and joints properly