- 59 -
n Dsen.Delay Some segment time which begin after open door
just begin alarm;
n Dsen. mode there are three option that is none( NONE),
normal open (NO), normal close(NC) .the none means the
door Sensor doesn’t apply, Normal Open is defined that Thee
door can be set to a Passage Mode in the normal condition,
Normal Close means that the door is close in the normal work
condition..
n Duress Alarm Option: If the fingerprint registered has been
authenticated the system will send an alarm signal to prstate
someone is forced to open door. In the menu you can do to all
setting.
n Alarm Cnt (the amount of failure to verify), if times of user
failure to verify equal to the value set, the fingerprint machine
will send alarm signal.
n GroupVerType: this means user who belong to group use
verification type.
Note:This option also is an optional item. It only is owned by some
fingerprint access control machine, if this option is set as Y (yes), the
fingerprint machine is able to perform Multi-combination
verification.